Pallet Racking for Vietnamese Warehouses

ApexBeam supplies industrial pallet racking to Vietnamese manufacturers, distribution centres and systems integrators, with loads determined under TCVN 2737:2023 and steel design to TCVN 5575:2024 where those govern, or to EN 15512 / ANSI MH16.1 where your investor's specification requires it. All 14 system types are available, produced at audited partner plants under our QC and traceability protocol, with standard products typically shipping 20–30 days after order confirmation.

Vietnam Has No Rack-Specific National Standard

This is worth stating plainly, because it changes how a Vietnamese rack project is specified and reviewed.

Unlike Canada (which has CSA S345 for racks) or the United States (ANSI/MH16.1 referenced through the IBC), Vietnam has no dedicated national design standard for steel storage racks. What Vietnam has is a general load standard and a general steel design standard, plus a seismic standard. A rack structure is therefore designed by applying those general standards to the rack's specific structural behaviour — semi-rigid beam-to-upright connections, perforated cold-formed columns, and a sway frame in the down-aisle direction.

In practice this means one of two paths, and your project documentation should say which:

  • Vietnamese code path — loads from TCVN 2737:2023, steel verification to TCVN 5575:2024, seismic actions from TCVN 9386:2012 where required
  • International specification path — EN 15512 or ANSI/MH16.1 for the rack design, with Vietnamese load values where the local authority or your investor requires them

Foreign-invested plants in Vietnam frequently specify the second path, because the parent company's engineering standard is European or American. Both are legitimate; what is not acceptable is a calculation that mixes load factors from one system with resistance rules from another without stating the basis. We name the governing standard set on the calculation cover sheet.

The Load Standard Changed — and It Matters for Tall Racks

TCVN 2737:2023 replaced TCVN 2737:1995, issued under Decision 1341/QD-BKHCN dated 29 June 2023 and compiled by IBST (Institute for Building Science and Technology). The 1995 version had governed Vietnamese practice for nearly three decades. Many supplier quotations and older calculations in circulation still cite it.

The wind provisions were rewritten, not merely revised:

Aspect TCVN 2737:1995 TCVN 2737:2023
Wind method Static and dynamic components separated by a height threshold Gust Effect Factor (Gf) method, applied to all structures
Basic wind return period 20 years 10 years (3-second gust)
Wind pressure zones Zones with sub-zones (I-A, II-A, etc.) 5 main zones, sub-zones removed
Wind reliability factor γf 1.2 2.1
Ultimate limit state return period Implicit Approximately 430 years

The practical consequence is the part that affects your steel: the γf = 2.1 factor converts a 10-year service-level wind pressure into an ultimate-level event of roughly 430-year return period. Published comparisons indicate design wind loads for the ultimate limit state are around 1.5 to 2.3 times higher under the 2023 standard than under the 1995 version, while the characteristic load used for serviceability checks is lower.

For a tall rack-clad structure or a high-bay AS/RS installation, that is not a marginal difference. It drives larger upright sections, heavier bracing, higher anchor tension and larger base plates. A rack-clad building quoted on 1995 wind values may be materially under-designed for the current code. We ask which edition your reviewer will enforce before issuing calculations, and we state it explicitly.

The 2023 standard also aligns its philosophy with EN 1990 / EN 1991 and borrows the Gf formulation from ASCE 7-16, while retaining importance factors from the Russian lineage. Because it draws from several source systems, some provisions require engineering judgement rather than mechanical application — another reason we confirm the basis with your consultant rather than assuming.

Steel Design and Seismic

TCVN 5575:2024, issued 24 December 2024, replaces TCVN 5575:2012 as the steel structure design standard. It is developed with reference to SP 16.13330.2017 (Steel structures) and its amendments, continuing the Russian code lineage that Vietnamese steel design has followed. If your reviewer's reference library still holds the 2012 edition, the calculation basis should be reconciled before submission.

Seismic actions follow TCVN 9386:2012, which is derived from EN 1998-1 (Eurocode 8). Reference peak ground acceleration agR is mapped by location, with values including 0.04g, 0.06g and 0.12g across the country. Seismic demand is not uniform: the northwestern region carries materially higher hazard than the southern delta, so a national default is not appropriate. Send your site location or the seismic parameters from your structural engineer and we calculate to them. Where the project specification calls for EN 16681 or FEM 10.2.08 rack-specific seismic verification instead, we work to that and say so. See our seismic design guide for methodology.

Applicable Standards

Standard What It Covers How We Apply It
TCVN 2737:2023 Loads and actions, including wind, live, crane and accidental actions; load combinations Load derivation for Vietnamese sites; replaces TCVN 2737:1995
TCVN 5575:2024 Design of steel structures Steel member verification where the Vietnamese code path governs; replaces TCVN 5575:2012
TCVN 9386:2012 Seismic actions and design of structures for earthquake resistance (from EN 1998-1) Applied where site hazard or specification requires seismic verification
EN 15512 European adjustable pallet racking design Our adjustable pallet racking is independently attested to EN 15512:2020+A1:2022 by UDEM (Cert. M.2023.206.C82720, valid to 13 March 2028)
EN 15620 Tolerances, deformations and clearances Verified for VNA and automated systems where crane or truck guidance depends on tight rack geometry
ANSI/MH16.1 (RMI) US design, testing and utilization specification Applied where your investor's or consultant's specification requires it
EN 16681 / FEM 10.2.08 Rack-specific seismic design Used where the project specification calls for rack seismic verification rather than general building seismic rules

Note on attestations: the UDEM certificate covers EN 15512. Conformity with TCVN standards on your project is achieved through our own structural design and verification, documented in the signed calculation report supplied with every order. We do not hold a Vietnamese product certification for racking, and we do not represent otherwise.

Typhoon Exposure and Anchorage

Vietnam's long coastline is exposed to typhoons, and this affects racking in two distinct ways depending on whether the rack is inside a building or is the building.

Rack-supported buildings are directly wind-loaded. Where the racking carries roof and wall cladding — a rack-supported building — the structure resists the full wind envelope, and the increased ULS wind values under TCVN 2737:2023 apply directly to upright sizing, bracing and anchorage. Wind uplift on the roof transfers into anchor tension at the base, which is frequently the governing check rather than pallet load. We model storage loads and envelope loads in a single structural calculation.

Racks inside a building are not wind-loaded, but anchorage still matters. For an internal installation the wind does not reach the rack; what governs is seismic action where applicable, forklift impact, and the down-aisle sway behaviour of the semi-rigid frame. It is worth being precise about this rather than applying typhoon language to every project — an internal selective rack in a sealed building is not a wind-resisting structure.

Coastal and delta humidity drives finish selection. High year-round humidity, condensation cycling in chilled areas, and marine chloride near the coast all attack a standard powder-coat-only specification. For coastal sites and unheated or semi-open structures we specify hot-dip galvanizing, or a zinc-rich primer plus topcoat system. For cold storage and freezer service, steel grade and impact toughness are selected for the operating temperature — Q235D or Q355D for sub-zero duty — with mill test certificates traceable per coil batch. Ambient dry warehouses inside a sealed envelope are well served by powder coating to a specified film thickness and RAL colour.

Systems Most Often Specified

System Why It Fits Vietnamese Operations Key Parameters
AS/RS Racking High-bay automated finished-goods storage on tight factory footprints; land cost and labour trends favour automation 500–3,000 kg per unit load · 24 m delivered · ±2–5 mm positioning
Selective Pallet Rack Mixed-SKU manufacturing and 3PL; 100% direct access for multi-client separation Load per level up to 3,000 kg (UDL) · Frames to 18 m · Beam length 1,500–3,600 mm
Drive-In Rack Bulk food, beverage and commodity storage with low SKU counts 500–1,500 kg/pallet · 2–10 pallets deep · Up to 10 m
Shuttle Rack Deep-lane semi-automated storage; reduces forklift traffic inside the rack 500–1,500 kg/pallet · 5–20+ pallets deep
Radio Shuttle 4-Way High-density multi-directional handling for high-throughput distribution Configured per project
Rack Supported Building One integrated structure instead of building plus racks; wind envelope resolved with the rack model 500–2,000 kg/position · 37 m delivered

Specifications are standard configuration ranges for preliminary selection; final values are confirmed by engineered calculation and drawings for each project.

Logistics and Documentation

Vietnam is reached by short-sea routing from South China ports, and by road through the northern border for sites in the Red River delta. Major deep-water gateways include Hai Phong and Lach Huyen in the north and Cai Mep – Thi Vai in the south, with inland haulage differing materially between the two deltas. Because transit is short, production sequencing rather than ocean time is usually the critical path — we schedule against your target on-site date and tell you plainly when a routing choice affects it.

Every shipment includes engineered layout drawings, the structural calculation report (signed and version-controlled, naming the governing standard edition), installation manual with torque specifications and anchor patterns, rated load notices per rack section, a container loading plan optimized for stowage and weight distribution, and mill test certificates. Third-party inspection can be arranged at raw material receipt, in-process or pre-shipment, with agency access and documentation coordinated by us.

Load notices and installation documentation are issued in English, Vietnamese, or bilingual on request. Tell us your site's operating language at enquiry stage so the documentation package is prepared correctly rather than reissued after delivery.

Delivered Experience

ApexBeam has supplied a 35 m high-bay AS/RS structure for a tyre manufacturer in Vietnam, delivering 26,632 pallet positions of finished-goods storage integrated into a tight site footprint at a new production plant. At 35 m, wind, seismic and crane-induced lateral loads became the governing design case rather than pallet weight: upright stability and base-plate anchorage were verified against both EN 15512 and EN 16681 load combinations. Tyre loads are bulky and uniformly distributed, which drove deep beam spans and high beam-end connector forces at every level.

The structural calculation included dynamic load factors for crane acceleration and braking. Tolerance verification was staged at defined heights during erection rather than checked only at completion — at that height, cumulative erection deviation leaves no margin at the crane mast guidance interface. Primary steel was supplied in Q355D with mill test certificates traced per coil batch, and installation supervision covered plumb, rail alignment and anchor torque at every stage. The crane-rack interface was commissioned without tolerance rework. See project cases for technical detail.

Beyond Vietnam, representative capability references include a 37 m self-supporting rack-clad building (over 10,000 pallet positions) designed to FEM 10.2.03 with seismic verification to local code, a 30 m cold-store AS/RS in Malaysia, and a 26.7 m food-industry AS/RS in Canada.

FAQ

Is there a Vietnamese national standard for pallet racking?

Not a rack-specific one. Vietnam has TCVN 2737:2023 for loads and actions, TCVN 5575:2024 for steel structure design, and TCVN 9386:2012 for seismic actions. A rack is designed by applying those general standards to rack-specific structural behaviour, or to EN 15512 / ANSI MH16.1 where your investor's specification requires it. We state which basis governs on the calculation cover sheet rather than implying a single standard covers everything.

Which edition of TCVN 2737 should my calculation use?

TCVN 2737:2023 replaced TCVN 2737:1995 under Decision 1341/QD-BKHCN of 29 June 2023. The wind provisions changed substantially — the Gust Effect Factor method replaced the old static/dynamic split, the basic wind return period moved from 20 to 10 years, and the wind reliability factor rose from 1.2 to 2.1, giving an ultimate limit state return period of roughly 430 years. Published comparisons put ULS design wind loads at about 1.5–2.3 times the old values. We confirm the edition your reviewer enforces before issuing calculations.

Does the higher wind load affect a rack inside an existing building?

Not directly — wind does not reach an internal rack. What governs there is seismic action where applicable, forklift impact and down-aisle sway behaviour. The increased wind values matter for rack-supported buildings, where the racking carries the roof and wall cladding and resists the full wind envelope including roof uplift into anchor tension.

Which steel design standard applies?

TCVN 5575:2024, issued 24 December 2024, replaces TCVN 5575:2012. It is developed with reference to SP 16.13330.2017. Where your project follows the European or American rack standard instead, we design to that and state it, with Vietnamese load values where required.

How do you handle seismic design in Vietnam?

Seismic actions follow TCVN 9386:2012, derived from EN 1998-1, with reference peak ground acceleration mapped by location. Demand is not uniform — the northwest carries higher hazard than the southern delta. Send your site location or your engineer's seismic parameters. Where the specification calls for rack-specific EN 16681 or FEM 10.2.08 verification, we work to that instead and say so.

What finish for a coastal or humid site?

Coastal chloride exposure and high year-round humidity warrant hot-dip galvanizing or a zinc-rich primer plus topcoat system rather than powder coating alone. For freezer service, grade and impact toughness are selected for operating temperature — Q235D or Q355D for sub-zero duty. Sealed, dry, ambient warehouses inside an insulated envelope are well served by powder coating to a specified film thickness.

Can load notices be issued in Vietnamese?

Yes. Load notices, installation manuals and safety documentation are issued in English, Vietnamese or bilingual on request. Tell us the operating language at enquiry stage.

What information do you need to quote a Vietnamese project?

Warehouse drawings or dimensions including clear height and column positions, pallet size and weight per loaded pallet, required positions, SKU count and turnover rules, forklift or crane type, your province and site address (for wind zone, seismic parameters and finish selection), the code edition or investor specification if already issued, and your documentation language. Standard products typically ship 20–30 days after order confirmation.

Request a Layout & Quote

Send us your warehouse floor plan or dimensions (length × width × clear height, including column positions), pallet size and weight per loaded pallet, required pallet positions, SKU profile, forklift or stacker crane type, and your province and site address so we can address wind zone, seismic parameters and finish selection. If your investor or consultant has already issued a design standard or load specification, include it. Our structural team returns a free layout drawing with a load calculation — no obligation.

  • Email: sales@njapexbeam.com
  • Phone / WhatsApp: +86 185 1251 6598

Request an Engineered Layout & Quote

Send your floor plan, pallet dimensions and weights, clear height and SKU profile. Our structural team returns a free layout drawing with a load calculation within 24 hours.

sales@njapexbeam.com   +8618512516598